    題名: Portable sleep monitoring by ECG and accelerator and bluetooth transmission
    作者: Chang, Kang-Ming;Liu, Shing-Hong
    貢獻者: Department of Computer and Communication Engineering
    關鍵詞: Acceleration;Biomedical engineering;Bluetooth;Electrocardiography;Electrochromic devices;Monitoring;Sensors;Accelerator;Bluetooth chip;ECG sensors;LabViEW;Low Power;Monitoring system;Remote monitoring;Sleep disorders;Sleep stage
    日期: 2009
    上傳時間: 2010-04-08 12:09:56 (UTC+0)
    出版者: Asia University
    摘要: Portable sleep monitoring has an increasing demand due to the increasing amount of sleep disorder patients. The HRV and sleep posture changed with different sleep stages. This paper therefore proposed a portable sleep monitoring system based on ECG and accelerator signals. This system contained single ECG sensor and a tri-axis accelerator sensor, with microcontroller MSP430 for low power analog-to-digital conversion, and signals transmitted through embedded Bluetooth chip. Remote monitoring of sleep posture and ECG was implemented in a Labview based interface.
    關聯: Proceedings of the 2009 2nd International Conference on Biomedical Engineering and Informatics, BMEI 2009