ASIA unversity:Item 310904400/8009
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94286/110023 (86%)
造訪人次 : 21668032      線上人數 : 1042
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://asiair.asia.edu.tw/ir/handle/310904400/8009


    題名: Supercritical fluid extraction of imidazole drugs from cosmetic and pharmaceutical products
    作者: Chou, W. L.;Chang, C. Y.;Liu, H. M.*;Yang, K. C.;Wu, C. C.
    貢獻者: Department of Biotechnology
    關鍵詞: supercritical fluid extraction;clotrimazole (CT);ketoconazole (KCZ);imidazole drugs
    日期: 2007
    上傳時間: 2010-03-15 08:11:24 (UTC+0)
    出版者: Asia University
    摘要: An effective method for isolating common imidazole drugs clotrimazole (CT) and ketoconazole (KCZ) from cosmetic and
    pharmaceutical products based on supercritical fluid extraction (SFE) was developed. Creams, tablets and cosmetic shampoos underwent supercritical carbon dioxide fluid extraction and CT and KCZ were determined by reverse-phase high performance liquid chromatography. All supercritical fluid extractions were performed with a 10-min static step, followed by a 15 min dynamic step using acetonitrile as the modifier. After extraction by SFE, KCZ and CT were separated on a C18 column using an isocratic mobile phase that consisted of methanol/water/diethylamine/glacial acetic acid (80:20:0.3:0.2, v/v, pH 7.0) at a flow rate of 1.0 mL/min. The eluates from column were monitored by absorbance at 224 nm using a diode array detector. This developed approach was validated by assaying commercial pharmaceuticals for the routine quantification of CT and KCZ in various formulations. The calibration curves for CT and KCZ were linear over the ranges of 50~250 μg/mL and 25~250 μg/mL, respectively. The detection limits of CT and KCZ were 2.31 μg/mL and 0.42 μg/mL, respectively, and the limits of quantitation were 7.70 μg/mL and 1.40 μg/mL, respectively. These drugs contents were found to be in good agreement with the label claim values. Satisfactory extraction recoveries ranging from 90.8% to 97.2% were obtained from five replicate extractions.
    關聯: Journal of Food and Drug Analysis 15:25-32
    顯示於類別:[生物科技學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    0KbUnknown330檢視/開啟
    310904400-8009.doc34KbMicrosoft Word171檢視/開啟


    在ASIAIR中所有的資料項目都受到原著作權保護.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋