English  |  正體中文  |  简体中文  |  Items with full text/Total items : 94286/110023 (86%)
Visitors : 21663214      Online Users : 523
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://asiair.asia.edu.tw/ir/handle/310904400/8009


    Title: Supercritical fluid extraction of imidazole drugs from cosmetic and pharmaceutical products
    Authors: Chou, W. L.;Chang, C. Y.;Liu, H. M.*;Yang, K. C.;Wu, C. C.
    Contributors: Department of Biotechnology
    Keywords: supercritical fluid extraction;clotrimazole (CT);ketoconazole (KCZ);imidazole drugs
    Date: 2007
    Issue Date: 2010-03-15 08:11:24 (UTC+0)
    Publisher: Asia University
    Abstract: An effective method for isolating common imidazole drugs clotrimazole (CT) and ketoconazole (KCZ) from cosmetic and
    pharmaceutical products based on supercritical fluid extraction (SFE) was developed. Creams, tablets and cosmetic shampoos underwent supercritical carbon dioxide fluid extraction and CT and KCZ were determined by reverse-phase high performance liquid chromatography. All supercritical fluid extractions were performed with a 10-min static step, followed by a 15 min dynamic step using acetonitrile as the modifier. After extraction by SFE, KCZ and CT were separated on a C18 column using an isocratic mobile phase that consisted of methanol/water/diethylamine/glacial acetic acid (80:20:0.3:0.2, v/v, pH 7.0) at a flow rate of 1.0 mL/min. The eluates from column were monitored by absorbance at 224 nm using a diode array detector. This developed approach was validated by assaying commercial pharmaceuticals for the routine quantification of CT and KCZ in various formulations. The calibration curves for CT and KCZ were linear over the ranges of 50~250 μg/mL and 25~250 μg/mL, respectively. The detection limits of CT and KCZ were 2.31 μg/mL and 0.42 μg/mL, respectively, and the limits of quantitation were 7.70 μg/mL and 1.40 μg/mL, respectively. These drugs contents were found to be in good agreement with the label claim values. Satisfactory extraction recoveries ranging from 90.8% to 97.2% were obtained from five replicate extractions.
    Relation: Journal of Food and Drug Analysis 15:25-32
    Appears in Collections:[生物科技學系] 期刊論文

    Files in This Item:

    File Description SizeFormat
    0KbUnknown327View/Open
    310904400-8009.doc34KbMicrosoft Word171View/Open


    All items in ASIAIR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback