ASIA unversity:Item 310904400/18808
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94286/110023 (86%)
造访人次 : 21713963      在线人数 : 402
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    ASIA unversity > 資訊學院 > 資訊工程學系 > 期刊論文 >  Item 310904400/18808


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://asiair.asia.edu.tw/ir/handle/310904400/18808


    题名: Computer Aided Classification System for Breast Ultrasound Based on BI-RADS
    作者: 沈偉誌;Shen, Wei-Chih
    贡献者: 資訊工程學系
    关键词: Breast cancer;Ultrasound image;BI-RADS;Computer-aided classification (CAC) system;Computer-aided diagnosis (CAD) system;Logistic regression
    日期: 2007
    上传时间: 2012-11-26 05:58:52 (UTC+0)
    摘要: Clinically, the ultrasound findings are evaluated by its sonographic characteristics and then assigned to assessment categories according to the definitions of Breast Imaging Reporting and Data System (BI-RADS) developed by the American College of Radiology. In this study, a computer-aided classification (CAC) system was proposed to classify the masses into assessment categories 3, 4 and 5, which simulated the clinical diagnosis of radiologists. Compared with current computer-aided diagnosis systems, the proposed CAC system classifies the indeterminate cases into BI-RADS category 4 for further diagnosis. Six hundred twenty-six cases were collected from three ultrasound systems and confirmed by pathology and retrospectively classified into categories 3, 4 and 5 by radiologists. The multinomial logistic regression model was trained as the CAC system for predicting the assessment category from the computerized BI-RADS features and from a set of machine-dependent factors. By using the machine-dependent factors to indicate the adopted ultrasound systems, the same regression model could be applied for the cases acquired from different ultrasound systems. A basic CAC system was trained by using the classification result of radiologists. A weighted CAC system, to improve the capacity of the basic CAC system in differentiating benign from malignant lesions, was trained by adding the pathologic result. Between the radiologists and the basic CAC system, a substantial agreement was indicated by Cohen's kappa statistic and the differences in either the performance indices or the A(Z) of receiver operating characteristic (ROC) analysis were not statistically significant. For the weighted CAC system, the performance indices accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 73.00% (457 of 626), 98.17% (215 of 219), 59.46% (242 of 407), 56.58% (215 of 380) and 98.37% (242 of 246), respectively; the A(Z) was 0.94; and the correlation with the radiologists was also substantial agreement. The indices accuracy and specificity of weighted CAC system, compared with those of the radiologists, were improved by 5.91% and 8.85%, respectively and the indices of sensitivity and NPV, compared with those of a conventional CAD system, were improved by 10.5% and 5.21%, respectively; all improvements were statistically significant. To classify the mass into BI-RADS assessment categories by the CAC system is feasible. Moreover, the proposed CAC system is flexible because it can be used to diagnose the cases acquired from different ultrasound systems.
    關聯: Ultrasound in Medicine and Biology; 33(11):1688-1698.
    显示于类别:[資訊工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML267检视/开启


    在ASIAIR中所有的数据项都受到原著作权保护.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈