ASIA unversity:Item 310904400/112807
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 94286/110023 (86%)
Visitors : 21651759      Online Users : 431
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://asiair.asia.edu.tw/ir/handle/310904400/112807


    Title: Biomechanical Performance of the Cemented Hip Stem with Different Surface Finish
    Authors: Hung, Jui-Pi;Hung, Jui-Pin;Bai, Yu-Wei;Bai, Yu-Wei;Hung, Chung-;Hung, Chung-Qua;李翠娥;Lee, Tsui-Er
    Contributors: 體育室
    Keywords: aseptic loosening;cemented implant;interfacial strength;surface finish
    Date: 2019-10
    Issue Date: 2020-08-31 06:07:11 (UTC+0)
    Publisher: 亞洲大學
    Abstract: The integrity of the cemented fixation interface is responsible for the long-term longevity of artificial hip prostheses. Metallic stems with roughened surfaces are considered to provide stronger adhesion with cement. However, clinical studies have reported that roughened stems show a lower survival rate than polished stems. These studies clearly reveal that the causes of artificial stem loosening are very complicated and multifaceted. Therefore, this study was conducted to investigate the mechanical effect of stem surface finish in cemented hip replacement. To accomplish this, a series of cement–metal specimens were tested configurations to assess the mechanical characteristics of the cement–metal interface specimens. A finite elemental model of cemented femoral prostheses was then created, in which the cement–stem interface was assumed to be in different bonding states according to the experimentally measured interface properties. The failure probabilities of the cement mantle and cemented interface under physiological loadings were evaluated. Experimental results indicate that the polished metal produced higher interfacial tensile and lower shearing strengths than the roughened metal. The polished stems were predicted to induce a lower failure probability of cement mantle and higher integrity of the cement–stem interface when compared to the roughened stem. Overall, current results provide significant evidence to support the clinical outcomes of cemented hip prostheses with different stem surface finishes.
    Relation: Applied Sciences-Basel
    Appears in Collections:[Office of Physical Education] Journal Article

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML278View/Open


    All items in ASIAIR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback